Marc Horner, Ph.D. - Publications

Affiliations: 
2002 Northwestern University, Evanston, IL 
Area:
Chemical Engineering

23 high-probability publications. We are testing a new system for linking publications to authors. You can help! If you notice any inaccuracies, please sign in and mark papers as correct or incorrect matches. If you identify any major omissions or other inaccuracies in the publication list, please let us know.

Year Citation  Score
2020 Viceconti M, Pappalardo F, Rodriguez B, Horner M, Bischoff J, Musuamba Tshinanu F. In Silico Trials: Verification, Validation And Uncertainty Quantification Of Predictive Models Used In The Regulatory Evaluation Of Biomedical Products. Methods (San Diego, Calif.). PMID 31991193 DOI: 10.1016/J.Ymeth.2020.01.011  0.33
2019 Morrison TM, Hariharan P, Funkhouser CM, Afshari P, Goodin M, Horner M. Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps. Asaio Journal (American Society For Artificial Internal Organs : 1992). PMID 30973403 DOI: 10.1097/Mat.0000000000000996  0.356
2018 Wilson JT, Edgar LT, Prabhakar S, Horner M, van Loon R, Moore JE. A fully coupled fluid-structure interaction model of the secondary lymphatic valve. Computer Methods in Biomechanics and Biomedical Engineering. 1-11. PMID 30398077 DOI: 10.1080/10255842.2018.1521964  0.367
2018 Mulugeta L, Drach A, Erdemir A, Hunt CA, Horner M, Ku JP, Myers JG, Vadigepalli R, Lytton WW. Credibility, Replicability, and Reproducibility in Simulation for Biomedicine and Clinical Applications in Neuroscience. Frontiers in Neuroinformatics. 12: 18. PMID 29713272 DOI: 10.3389/Fninf.2018.00018  0.324
2017 Hariharan P, D'Souza GA, Horner M, Morrison TM, Malinauskas RA, Myers MR. Use of the FDA nozzle model to illustrate validation techniques in computational fluid dynamics (CFD) simulations. Plos One. 12: e0178749. PMID 28594889 DOI: 10.1371/Journal.Pone.0178749  0.375
2017 Horner M. Special Issue: Cardiovascular Device Development and Safety Assessment Using Computational Modeling and Experimental Approaches Journal of Medical Devices. 11. DOI: 10.1115/1.4036591  0.305
2015 Horner M, Metcalfe G, Ottino JM. Convection-Enhanced Transport into Open Cavities : Effect of Cavity Aspect Ratio. Cardiovascular Engineering and Technology. 6: 352-63. PMID 26577366 DOI: 10.1007/S13239-015-0217-Y  0.554
2015 Hariharan P, D'Souza GA, Horner M, Malinauskas RA, Myers M. Verification benchmarks to assess the implementation of computational fluid dynamics based hemolysis prediction models. Journal of Biomechanical Engineering. PMID 26065371 DOI: 10.1115/1.4030823  0.405
2015 Saylor DM, Soneson JE, Kleinedler JJ, Horner M, Warren JA. A structure-sensitive continuum model of arterial drug deposition International Journal of Heat and Mass Transfer. 82: 468-478. DOI: 10.1016/J.Ijheatmasstransfer.2014.10.059  0.309
2014 Marom G, Chiu WC, Crosby JR, DeCook KJ, Prabhakar S, Horner M, Slepian MJ, Bluestein D. Numerical model of full-cardiac cycle hemodynamics in a total artificial heart and the effect of its size on platelet activation. Journal of Cardiovascular Translational Research. 7: 788-96. PMID 25354999 DOI: 10.1007/S12265-014-9596-Y  0.347
2013 Karmonik C, Yen C, Gabriel E, Partovi S, Horner M, Zhang YJ, Klucznik RP, Diaz O, Grossman RG. Quantification of speed-up and accuracy of multi-CPU computational flow dynamics simulations of hemodynamics in a posterior communicating artery aneurysm of complex geometry. Journal of Neurointerventional Surgery. 5: iii48-55. PMID 23482710 DOI: 10.1136/Neurintsurg-2012-010586  0.36
2012 Gohel S, Joshi S, Azhar M, Horner M, Padron G. CFD modeling of solid suspension in a stirred tank: Effect of drag models and turbulent dispersion on cloud height International Journal of Chemical Engineering. DOI: 10.1155/2012/956975  0.315
2010 Missel PJ, Horner M, Muralikrishnan R. Simulating dissolution of intravitreal triamcinolone acetonide suspensions in an anatomically accurate rabbit eye model. Pharmaceutical Research. 27: 1530-46. PMID 20467888 DOI: 10.1007/S11095-010-0163-1  0.31
2010 Horner M, Joshi S, Dhruva V, Sett S, Stewart SFC. A Two-Species Drug Delivery Model is Required to Predict Deposition from Drug-Eluting Stents Cardiovascular Engineering and Technology. 1: 225-234. DOI: 10.1007/S13239-010-0016-4  0.31
2009 Lyczkowski RW, Alevriadou BR, Horner M, Panchal CB, Shroff SG. Application of multiphase computational fluid dynamics to analyze monocyte adhesion. Annals of Biomedical Engineering. 37: 1516-33. PMID 19521774 DOI: 10.1007/S10439-009-9729-7  0.392
2008 Fill B, Gartner M, Johnson G, Horner M, Ma J. Computational fluid flow and mass transfer of a functionally integrated pediatric pump-oxygenator configuration. Asaio Journal (American Society For Artificial Internal Organs : 1992). 54: 214-9. PMID 18356659 DOI: 10.1097/Mat.0B013E3181648D80  0.396
2008 Dasgupta S, Bhagat AAS, Horner M, Papautsky I, Banerjee RK. Effects of applied electric field and microchannel wetted perimeter on electroosmotic velocity Microfluidics and Nanofluidics. 5: 185-192. DOI: 10.1007/S10404-007-0236-6  0.312
2007 Wang C, Pekkan K, de Zélicourt D, Horner M, Parihar A, Kulkarni A, Yoganathan AP. Progress in the CFD modeling of flow instabilities in anatomical total cavopulmonary connections. Annals of Biomedical Engineering. 35: 1840-56. PMID 17641974 DOI: 10.1007/S10439-007-9356-0  0.412
2006 Fill BJ, Gartner MJ, Johnson G, Ma J, Horner M. POROUS MEDIA TECHNIQUE FOR COMPUTATIONAL MODELING OF A NOVEL PUMP-OXYGENATOR Asaio Journal. 52: 28A. DOI: 10.1097/00002480-200603000-00126  0.315
2006 Fill B, Gartner M, Johnson G, Ma J, Horner M. Computational flow and mass transfer analysis of a pump-oxygenator Journal of Biomechanics. 39: S255. DOI: 10.1016/S0021-9290(06)83969-2  0.34
2002 Horner M, Metcalfe G, Wiggins S, Ottino JM. Transport enhancement mechanisms in open cavities Journal of Fluid Mechanics. 452: 199-229. DOI: 10.1017/S0022112001006917  0.525
1998 Horner M, Miller WM, Ottino JM, Papoutsakis ET. Transport in a grooved perfusion flat-bed bioreactor for cell therapy applications. Biotechnology Progress. 14: 689-98. PMID 9758657 DOI: 10.1021/Bp980067E  0.507
1995 Horner M, Arce P, Locke BR. Convective-Diffusive Transport and Reaction in Arterial Stenoses Using Lubrication and Area-Averaging Methods Industrial & Engineering Chemistry Research. 34: 3426-3436. DOI: 10.1021/Ie00037A031  0.307
Show low-probability matches.